E1S系列小型富士变频器维修:
1. FRN0.4E1S-4C 1. 1KVA 1.5A 0.4KW 3相AC380V/50Hz/60Hz
2. FRN0.75E1S-4C 1. 9KVA 2.5A 0.75KW 3相AC380V/50Hz/60Hz
3. FRN1.5E1S-4C 2. 8KVA 3.7A 1.5KW 3相AC380V/50Hz/60Hz无锡富士变频器维修可以选择
4. FRN2.2E1S-4C 4. 1KVA 5.5A 2.2KW 3相AC380V/50Hz/60Hz
5. FRN3.7E1S-4C 6. 8KVA 9.0A 3.7KW 3相AC380V/50Hz/60Hz
6. FRN5.5E1S-4C 9.9 KVA 13 A 5.5KW 3相AC380V/50Hz/60Hz
7. FRN7.5E1S-4C 13 KVA 18 A 7.5KW 3相AC380V/50Hz/60Hz
8. FRN11E1S-4C 18 KVA 24 A 11KW 3相AC380V/50Hz/60Hz
9. FRN15E1S-4C 22 KVA 30 A 15KW 3相AC380V/50Hz/60Hz
10. FRN0.4E1S-7C 1.1 KVA 3.0A 0.4KW 单相AC220V/50Hz/60Hz
11. FRN0.75E1S-7C 1.9 KVA 5.0A 0.75KW 单相AC220V/50Hz/60Hz
12. FRN1.5E1S-7C 3.0 KVA 8.0A 1.5KW 单相AC220V/50Hz/60Hz
13. FRN2.2E1S-7C 4.1 KVA 11 A 2.2KW 单相AC220V/50Hz/60Hz
C1S系列小型富士变频器维修:
1. FRN0.4C1S-4C 1. 2KVA 1.6A 0.4KW 3相AC380V/50Hz/60Hz
2. FRN0.75C1S-4C 1. 9KVA 2.5A 0.75KW 3相AC380V/50Hz/60Hz
3. FRN1.5C1S-4C 2. 8KVA 3.7A 1.5KW 3相AC380V/50Hz/60Hz 无锡富士变频器维修可以选择
4. FRN2.2C1S-4C 4. 2KVA 5.5A 2.2KW 3相AC380V/50Hz/60Hz
5. FRN3.7C1S-4C 6. 9KVA 9.0A 3.7KW 3相AC380V/50Hz/60Hz
6. FRN0.4C1S-7C 1. 1KVA 3.0A 0.4KW 单相AC220V/50Hz/60Hz
7. FRN0.75C1S-7C 1. 9KVA 5.0A 0.75KW 单相AC220V/50Hz/60Hz
8. FRN1.5C1S-7C 3. 0KVA 8.0A 1.5KW 单相AC220V/50Hz/60Hz 无锡富士厂商维修,售后,技术服务
9. FRN2.2C1S-7C 4. 2KVA 11.0A 2.2KW 单相AC220V/50Hz/60Hz
VG7S系列小型富变频器维修:
1. FRN0.4G11S-4CX 1.1KVA 1.5A 0.4 KW 3相AC380V/50Hz/60Hz
2. FRN0.75G11S-4CX 1.9KVA 2.5A 0.75KW 3相AC380V/50Hz/60Hz
3. FRN1.5G11S-4CX 2.8KVA 3.7A 1.5 KW 3相AC380V/50Hz/60Hz
4. FRN2.2G11S-4CX 4.2KVA 5.5A 2.2 KW 3相AC380V/50Hz/60Hz
5. FRN3.7G11S-4CX 6.9KVA 9.0A 3.7 KW 3相AC380V/50Hz/60Hz
6. FRN5.5G11S-4CX 10 KVA 13 A 5.5 KW 3相AC380V/50Hz/60Hz
7. FRN7.5G11S-4CX 14 KVA 18 A 7.5 KW 3相AC380V/50Hz/60Hz
8. FRN11G11S-4CX 18 KVA 24 A 11 KW 3相AC380V/50Hz/60Hz
9. FRN15G11S-4CX 23 KVA 30 A 15 KW 3相AC380V/50Hz/60Hz
10. FRN18.5G11S-4CX 30 KVA 39 A 18.5KW 3相AC380V/50Hz/60Hz
11. FRN22G11S-4CX 34 KVA 45 A 22KW 3相AC380V/50Hz/60Hz
12. FRN30G11S-4CX 46 KVA 60 A 30KW 3相AC380V/50Hz/60Hz
13. FRN37G11S-4CX 57 KVA 75 A 37KW 3相AC380V/50Hz/60Hz 无锡富士厂商维修,售后,技术服务
14. FRN45G11S-4CX 69 KVA 91 A 45KW 3相AC380V/50Hz/60Hz
15. FRN55G11S-4CX 85 KVA 112A 55KW 3相AC380V/50Hz/60Hz
16. FRN75G11S-4CX 114KVA 150A 75KW 3相AC380V/50Hz/60Hz
17. FRN90G11S-4CX 134KVA 176A 90KW 3相AC380V/50Hz/60Hz
18. FRN110G11S-4CX 160KVA 210A 110KW 3相AC380V/50Hz/60Hz
19. FRN132G11S-4CX 193KVA 253A 132KW 3相AC380V/50Hz/60Hz
20. FRN160G11S-4CX 232KVA 304A 160KW 3相AC380V/50Hz/60Hz
21. FRN200G11S-4CX 287KVA 377A 200KW 3相AC380V/50Hz/60Hz
22. FRN220G11S-4CX 316KVA 415A 220KW 3相AC380V/50Hz/60Hz
23. FRN280G11S-4CX 396KVA 520A 280KW 3相AC380V/50Hz/60Hz
24. FRN315G11S-4CX 445KVA 585A 315KW 3相AC380V/50Hz/60Hz
25. FRN355G11S-4CX 495KVA 650A 355KW 3相AC380V/50Hz/60Hz
26. FRN400G11S-4CX 563KVA 740A 400KW 3相AC380V/50Hz/60Hz
24. FRN500G11S-4CX 500KW 3相AC380V/50Hz/60Hz 无锡富士变频器维修可以选择
25. FRN630G11S-4CX 630KW 3相AC380V/50Hz/60Hz
富士变频器维修F1S系列:
1. FRN3.7F1S-4C 6.8KVA 9.0A 3.7 KW 3相AC380V/50Hz/60Hz
2. FRN5.5F1S-4C 9.5KVA 12.5 A 5.5 KW 3相AC380V/50Hz/60Hz
3. FRN7.5F1S-4C 12KVA 16.5 A 7.5 KW 3相AC380V/50Hz/60Hz
4. FRN11F1S-4C 17KVA 23 A 11 KW 3相AC380V/50Hz/60Hz
5. FRN15F1S-4C 22KVA 30 A 15 KW 3相AC380V/50Hz/60Hz
无锡富士厂商维修,售后,技术服务6. FRN18.5F1S-4C 28 KVA 37 A 18.5KW 3相AC380V/50Hz/60Hz
7. FRN22F1S-4C 33 KVA 44 A 22KW 3相AC380V/50Hz/60Hz
8. FRN30F1S-4C 44 KVA 59 A 30KW 3相AC380V/50Hz/60Hz
9. FRN37F1S-4C 54 KVA 72 A 37KW 3相AC380V/50Hz/60Hz
无锡富士厂商维修,售后,技术服务10. FRN45F1S-4C 64 KVA 85 A 45KW 3相AC380V/50Hz/60Hz
11. FRN55F1S-4C 77 KVA 105A 55KW 3相AC380V/50Hz/60Hz
12. FRN75F1S-4C 105KVA 139A 75KW 3相AC380V/50Hz/60Hz
13. FRN90F1S-4C 128 KVA 168 A 90KW 3相AC380V/50Hz/60Hz
14. FRN110F1S-4C 154 KVA 203A 110KW 3相AC380V/50Hz/60Hz
15. FRN132F1S-4C 182KVA 240 A 132KW 3相AC380V/50Hz/60Hz
16. FRN160F1S-4C 221KVA 290 A 160KW 3相AC380V/50Hz/60Hz
17. FRN200F1S-4C 274 KVA 360 A 200KW 3相AC380V/50Hz/60Hz
18. FRN220F1S-4C 316 KVA 415 A 220KW 3相AC380V/50Hz/60Hz
19 FRN280F1S-4C 396 KVA 520A 280KW 3相AC380V/50Hz/60Hz
20 FRN315F1S-4C 445KVA 585 A 315KW 3相AC380V/50Hz/60Hz 无锡富士变频器维修可以选择
21 FRN355F1S-4C 495KVA 650 A 355KW 3相AC380V/50Hz/60Hz
22 FRN400F1S-4C 584 KVA 740 A 400KW 3相AC380V/50Hz/60Hz
23 FRN450F1S-4C 640 KVA 840A 450KW 3相AC380V/50Hz/60Hz
24 FRN500F1S-4C 731 KVA 960A 500KW 3相AC380V/50Hz/60Hz
24 FRN560F1S-4C KVA 1080A 560KW 3相AC380V/50Hz/60Hz
富士变频器维修常见故障及判断:
(1) OC报警
键盘面板LCD显示:加、减、恒速时过电流。
对于短时间大电流的OC报警,一般情况下是驱动板的电流检测回路出了问题,模块也可能已受到冲击(损坏),有可能复位后继续出现故障,产生的原因基本是以下几种情况:电机电缆过长、电缆选型临界造成的输出漏电流过大或输出电缆接头松动和电缆受损造成的负载电流升高时产生的电弧效应。
小容量(7.5G11以下)变频器的24V风扇电源短路时也会造成OC3报警,无锡富士变频器维修可以选择此时主板上的24V风扇电源会损坏,主板其它功能正常。若出现“1、OC2”报警且不能复位或一上电就显示“OC3”报警,则可能是主板出了问题;若一按RUN键就显示“OC3”报警,则是驱动板坏了。
(2) OLU报警无锡富士厂商维修,售后,技术服务
键盘面板LCD显示:变频器过负载。
当G/P9系列富士变频器维修出现此报警时可通过三种方法解决:首先修改一下“转矩提升”、“加减速时间”和“节能运行”的参数设置;其次用卡表测量变频器的输出是否真正过大;最后用示波器观察主板左上角检测点的输出来判断主板是否已经损坏。
(3) OU1报警
键盘面板LCD显示:加速时过电压。
当富士变频器维修中出现“OU”报警时,首先应考虑电缆是否太长、绝缘是否老化,直流中间环节的电解电容是否损坏,同时针对大惯量负载可以考虑做一下电机的在线自整定。另外在启动时用万用表测量一下中间直流环节电压,若测量仪表显示电压与操作面板LCD显示电压不同,则主板的检测电路有故障,需更换主板。当直流母线电压**780VDC时,变频器做OU报警;当低于350VDC时,富士变频器维修做欠压LU报警。
(4) LU报警无锡富士厂商维修,售后,技术服务
键盘面板LCD显示:欠电压。
如果设备经常“LU欠电压”报警,则可考虑将变频器的参数初始化(H03设成1后确认),然后提高变频器的载波频率(参数F26)。若E9设备LU欠电压报警且不能复位,无锡富士变频器维修可以选择则是(电源)驱动板出了问题。
(5) EF报警
键盘面板LCD显示:对地短路故障。
G/P9系列富士变频器维修出现此报警时可能是主板或霍尔元件出现了故障。
(6) Er1报警
键盘面板LCD显示:存贮器异常。
关于G/P9系列富士变频器维修“ER1不复位”故障的处理:去掉FWD—CD短路片,上电、一直按住RESET键下电,知道LED电源指示灯熄灭再松手;然后再重新上电,看看“ER1不复位”故障是否解除,若通过这种方法也不能解除,则说明内部码已丢失,只能换主板了。
(7) Er7报警
键盘面板LCD显示:自整定不良。
G/P11系列富士变频器维修出现此故障报警时,一般是充电电阻损坏(小容量变频器)。另外就是检查内部接触器是否吸合(大容量变频器,30G11以上;且当变频器带载输出时才会报警)、接触器的辅助触点是否接触良好;若内部接触器不吸合可首先检查驱动板上的1A保险管是否损坏。也可能是驱动板出了问题—可检查送给主板的两芯信号是否正常。无锡富士厂商维修,售后,技术服务
(8) Er2报警
键盘面板LCD显示:面板通信异常。
11kW以上的富士变频器维修当24V风扇电源短路时会出现此报警(主板问题)。对于E9系列机器,一般是显示面板的DTG元件损坏,该元件损坏时会连带造成主板损坏,表现为更换显示面板后上电运行时立即OC报警。而对于G/P9机器一上电就显示“ER2”报警,则是驱动板上的电容失效了。
(9) OH1过热报警
键盘面板LCD显示:散热片过热。
OH1和OH3实质为同一信号,是CPU随机检测的,无锡富士变频器维修可以选择OH1(检测底板部位)与OH3(检测主板部位)模拟信号串联在一起后再送给CPU,而CPU随机报其中任一故障。出现“OH1”报警时,首先应检查环境温度是否过高,冷却风扇是否工作正常,其次是检查散热片是否堵塞(食品加工和纺织场合会出现此类报警)。若在恒压供水场合且采用模拟量给定时,一般在使用800Ω电位器时*出现此故障;给定电位器的容量不能过小,不能小于1kΩ;电位器的活动端接错也会出现此报警。若大容量变频器(30G11以上)的220V风扇不转时,肯定会出现过热报警,此时可检查电源板上的保险管FUS2(600V,2A)是否损坏。
当出现“OH3”报警时,一般是驱动板上的小电容因过热失效,失效的结果(症状)是变频器的三相输出不平衡。因此,当变频器出现“OH1”或 “OH3”时,可首先上电检查变频器的三相输出是否平衡。
对于OH过热报警,主板或电子热计出现故障的可能性也存在。G/P11系列富士变频器维修,电子热计为模拟信号,G/P9系列变频器电子热计为开关信号。无锡富士厂商维修,售后,技术服务
(10) 1、OH2报警与OH2报警